MCT
Type
Immersion
Cooled
Wavelength
Package
\(Al_{2}O_{3}\)
Detectivity
Time constant
Check detectors to compare
Compare detectorsCheck to compare |
Name | Material | Type | Immersion | Cooling | Wavelength | Package | Window | Detectivity | Time constant |
---|---|---|---|---|---|---|---|---|---|---|
PC-2TE-4 | MCT | Photoconductive |
Non-immersion |
Two-stage |
4 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥2,0x10^{10}\) | \(≤30000\) | |
PC-2TE-5 | MCT | Photoconductive |
Non-immersion |
Two-stage |
5 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥1,0x10^{10}\) | \(≤20000\) | |
PCI-2TE-4 | MCT | Photoconductive |
Immersion |
Two-stage |
4 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥4,0x10^{10}\) | \(≤30000\) | |
PCI-2TE-5 | MCT | Photoconductive |
Immersion |
Two-stage |
5 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥2,0x10^{10}\) | \(≤20000\) | |
PV-2TE-3 | MCT | Photovoltaic |
Non-immersion |
Two-stage |
3 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥7,0x10^{10}\) | \(≤280\) | |
PV-2TE-3,4 | MCT | Photovoltaic |
Non-immersion |
Two-stage |
3,4 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥4,0x10^{10}\) | \(≤200\) | |
PV-2TE-4 | MCT | Photovoltaic |
Non-immersion |
Two-stage |
4 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥3,0x10^{10}\) | \(≤100\) | |
PV-2TE-5 | MCT | Photovoltaic |
Non-immersion |
Two-stage |
5 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥9,0x10^{9}\) | \(≤80\) | |
PV-3TE-3 | MCT | Photovoltaic |
Non-immersion |
Three-stage |
3 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥1,0x10^{11}\) | \(≤280\) | |
PV-3TE-3,4 | MCT | Photovoltaic |
Non-immersion |
Three-stage |
3,4 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥7,0x10^{10}\) | \(≤200\) | |
PV-3TE-4 | MCT | Photovoltaic |
Non-immersion |
Three-stage |
4 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥4,0x10^{10}\) | \(≤100\) | |
PV-3TE-5 | MCT | Photovoltaic |
Non-immersion |
Three-stage |
5 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥1,0x10^{10}\) | \(≤80\) | |
PV-4TE-3 | MCT | Photovoltaic |
Non-immersion |
Four-stage |
3 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥1,5x10^{11}\) | \(≤280\) | |
PV-4TE-3,4 | MCT | Photovoltaic |
Non-immersion |
Four-stage |
3,4 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥1,0x10^{11}\) | \(≤200\) | |
PV-4TE-4 | MCT | Photovoltaic |
Non-immersion |
Four-stage |
4 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥6,0x10^{10}\) | \(≤100\) | |
PV-4TE-5 | MCT | Photovoltaic |
Non-immersion |
Four-stage |
5 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥1,5x10^{10}\) | \(≤80\) | |
PVI-2TE-3 | MCT | Photovoltaic |
Immersion |
Two-stage |
3 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥5,5x10^{11}\) | \(≤280\) | |
PVI-2TE-3,4 | MCT | Photovoltaic |
Immersion |
Two-stage |
3,4 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥3,0x10^{11}\) | \(≤200\) | |
PVI-2TE-4 | MCT | Photovoltaic |
Immersion |
Two-stage |
4 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥2,0x10^{11}\) | \(≤100\) | |
PVI-2TE-5 | MCT | Photovoltaic |
Immersion |
Two-stage |
5 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥6,0x10^{10}\) | \(≤80\) | |
PVI-3TE-3 | MCT | Photovoltaic |
Immersion |
Three-stage |
3 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥7,0x10^{11}\) | \(≤280\) | |
PVI-3TE-3,4 | MCT | Photovoltaic |
Immersion |
Three-stage |
3,4 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥5,0x10^{11}\) | \(≤200\) | |
PVI-3TE-4 | MCT | Photovoltaic |
Immersion |
Three-stage |
4 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥3,0x10^{11}\) | \(≤100\) | |
PVI-3TE-5 | MCT | Photovoltaic |
Immersion |
Three-stage |
5 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥8,0x10^{10}\) | \(≤80\) | |
PVI-4TE-3 | MCT | Photovoltaic |
Immersion |
Four-stage |
3 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥8.0x10^{11}\) | \(≤280\) | |
PVI-4TE-3,4 | MCT | Photovoltaic |
Immersion |
Four-stage |
3,4 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥7.0x10^{11}\) | \(≤200\) | |
PVI-4TE-4 | MCT | Photovoltaic |
Immersion |
Four-stage |
4 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥4.0x10^{11}\) | \(≤100\) | |
PVI-4TE-5 | MCT | Photovoltaic |
Immersion |
Four-stage |
5 |
TO8 TO66 |
wedged \(Al_{2}O_{3}\) |
\(≥1.0x10^{11}\) | \(≤80\) |