PEM

PEM

Categories:
Detectors
Photoelectromagnetic

The PEM series detectors operate on the photoelectromagnetic effect in the semiconductors. The devices are typically optimized for the best performance at 10.6 μm.

The detector includes active element based on (HgCd)Te band gap engineered with selected composition and doping profiles, and miniature permanent magnets to produce a magnetic field. The PEM detectors are well suited for heterodyne detection of 10.6 μm radiation. Exhibiting no flicker noise, they can be at the same time used for detection of CW and low frequency modulated radiation in the whole 2 to 11 μm spectral range. Custom devices such as single elements of various sizes, quadrant cells and multielement arrays, various specialized packages and connectors are available upon request. Standard detectors are available in specialized PEM packages (with SMA connectors) with wZnSeAR windows.

Characteristics:

Features:

  • Ambient temperature operation
  • No bias required
  • 2 to 11 µm spectral range
  • Time constant of 1 ns or less
  • No flicker noise
  • Operation from DC to VHF
  • Lightweight, rugged and reliable
  • Convenient to use
  • Low cost
  • Custom design upon request
'
Parameter Symbol Unit PEMI-10,6 PEM-10,6
Material MCT MCT
Type Photoelectromagnetic Photoelectromagnetic
Immersion Immersion
Non-immersion
Cooling No
No
Wavelength \(λ_{opt}\) \(µm\) 10.6 10.6
Package PEM-SMA, PEM-TO8 PEM-SMA, PEM-TO8
Window wedged ZnSe AR coated wedged ZnSe AR coated
Detectivity \(D*\) \(cm⋅Hz^{1/2}⋅W^{-1}\) \(≥1,0x10^8\) \(≥1,0x10^7\)
Time constant \(τ\) \(ns\) \(≤1,2\) \(≤1,2\)
Detectivity numeric 100000000 10000000
Time constant numeric 1,2 1,2
Product group PEMI PEM
Type
Optical Area [mm×mm]
0.025×0.025
0.05×0.05
0.1×0.1
0.2×0.2
0.25×0.25
0.5×0.5
1×1
2×2
3×3
4×4
PEM-10.6
O
O
O
O
X
X

x – standard detectors
O – detectors available on request, parameters may vary from these in Data Sheet

Specyfikacja

Parameter
Symbol
Unit
PEM-10.6
Optimal Wavelenght
λopt
µm
10.6
Detectivity*):
@ λpeak
@ λopt
D*
cm⋅Hz1/2⋅W-1
≥3.0×107
≥1.0×107
Voltage Responsivity – Width Product
@ λopt, 1×1 mm
Rv⋅w
V⋅mm⋅W-1
≥0.1
Time Constant
τ
ns
≤1
Resistance
R
Ω
40 to 100
Operating Temperature
T
K
~300
Acceptance Angle, F/#
Φ, –
deg, –
51, 1.16

*) Data Sheet states minimum guaranteed D* values for each detector model. Higher performance detectors can be provided upon request.

Powierzchnia optyczna [mm x mm]

Do pobrania

Tel.: +48 22 733 54 10

ul. Poznańska 129/133 05-850 Ożarów Mazowiecki