PVM

PVM

8-11 μm IR PHOTOVOLTAIC MULTIPLE JUNCTION DETECTORS

Categories:
Detectors
Multiple junction

The PVM-λopt photodetectors series (λopt - optimal wavelength in micrometers) feature IR multiple junction photovoltaic detector. The devices are optimized for the maximum performance at λopt. Highest performance and stability are achieved by application of variable gap HgCdTe semiconductor, optimized doping and sophisticated surface processing. Standard detectors are available in TO39 or BNC packages without windows. Various windows, other packages and connectors are available upon request.

Characteristics:

Features:

  • Ambient temperature operation
  • No bias required
  • Short time constant
  • No flicker noise
  • Operation from DC to VHF
  • Perfect match to fast electronics
  • Wide dynamic range
  • Large area devices
  • Low cost
  • Prompt delivery
  • Custom design upon request
'
Parameter Symbol Unit PVM-10,6 PVM-8
Material MCT MCT
Type Multiple junction Multiple junction
Immersion Non-immersion
Non-immersion
Cooling No
No
Wavelength \(λ_{opt}\) \(µm\) 10,6 8
Package BNC, TO8, TO39 BNC, TO8, TO39
Window No No
Detectivity \(D*\) \(cm⋅Hz^{1/2}⋅W^{-1}\) \(≥1,0x10^{7}\) \(≥6,5x10^{7}\)
Time constant \(τ\) \(ns\) \(≤1,5\) \(≤4\)
Detectivity numeric 10000000 65000000
Time constant numeric 1,5 4
Product group PVM PVM
Type
Optical Area [mm×mm]
0.025×0.025
0.05×0.05
0.1×0.1
0.2×0.2
0.25×0.25
0.5×0.5
1×1
2×2
3×3
4×4
PVM-8
O
O
X
X
O
O
X
X
X
X
PVM-10.6
O
O
X
X
O
O
X
X
X
X

X – standard detectors
O – detectors available upon request, parameters may vary from these in Data Sheet

Cechy

  • Ambient temperature operation
  • No bias required
  • Short time constant
  • No flicker noise
  • Operation from DC to VHF
  • Perfect match to fast electronics
  • Wide dynamic range
  • Large area devices
  • Low cost
  • Prompt delivery
  • Custom design upon request

Specyfikacja

Parameter
Symbol
Unit
PVM-8
PVM-10.6
Optimal Wavelength
λopt
µm
8
10.6
Detectivity*):
peak
@ λopt
D*
cm⋅Hz1/2⋅W-1
≥1.2×108
≥6.0×107
≥2.0×107
≥1.0×107
Current Responsivity – Width Product
@ λopt, 1×1mm
Ri⋅w
A⋅mm⋅W-1
≥0.008
≥0.002
Time Constant
τ
ns
≤4
≤1.5
Resistance
R
Ω
50 to 300
20 to 150
Operating Temperature
T
K
~300
Acceptance Angle, F/#
Φ, –
deg, –
>90, 0.71

*) Data Sheet states minimum guaranteed D* values for each detector model. Higher performance detectors can be provided upon request.

Powierzchnia optyczna [mm x mm]

Type
Optical Area [mm×mm]
0.025×0.025
0.05×0.05
0.1×0.1
0.2×0.2
0.25×0.25
0.5×0.5
1×1
2×2
3×3
4×4
PVM-8
O
O
X
X
O
O
X
X
X
X
PVM-10.6
O
O
X
X
O
O
X
X
X
X

X – standard detectors
O – detectors available upon request, parameters may vary from these in Data Sheet